Go
to ETS Main Page
Go to Systems Integrator Specialty
Products
Main Page
ETS
Electronic Technical Services Inc.
211 Conchas SE
Albuquerque, NM 87123
Phone: 505-888-3923
Fax: 505-888-3926 Toll Free: 866-700-3923
E-mail: sales1@etsnm.com
Made in U.S.A. |
Relay Boards, Timer, Universal Voltage Regulator
|
RI16 Sixteen Channel Relay
Board
16 zone relay board accepts any
voltage from 5V to 24V ac or dc and
converts that signal into an
isolated, dry contact, normally
open output. The RI16 is
typically used to interface fire
alarm or industrial controls with
access control or alarm
systems. The RI16 can be
ordered with EOL relay output
resistors (specify values when
ordering) to make direct connections
to supervised alarm equipment inputs.
Recently updated to accept 5-24VDC or
5-24VAC input voltages, field replaceable
relays and smaller PCB size.
- Accepts Voltages from 5 to 24Vac or
5 to 24Vdc.
-
LED indicators for each
channel.
-
Each input contains a rectifier / Voltage regulator for constant Voltage
across relay coil regardless of input Voltage.
- 40ma current consumption per
channel max.
- 1 Amp relay output contact current
rating @ 48VDC
-
Socketed, field replaceable relays
- Optional single or dual EOL resistors can be installed in the relay
output contact circuit. (specify values when ordering)
- European-style, easy terminate,
input
and output connectors.
- Dimensions: W 2.9 x L 9.2
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|
GPRB-16 Sixteen Channel Relay
Board
The GPRB-16 is a 16 channel general
purpose relay board with form C outputs
(DPST) and the relay contact are rated at
8Amps. Each channel can be independently
configured for 12V or 24V AC or DC inputs
(6 and 12V version also available). Both the
input and output channels can be configured to
share a common connection (typically ground)
and this eliminates the need for installing small
jumper wires between channels in installations
where a common ground (or power) will be used.
- Accepts Voltages from 12 or 24V AC/DC,
Jumper selectable
- 6 or 12V AC/DC version available.
-
LED indicators for each
channel.
-
Form C (DPST) output contacts
-
Jumper selectable commons for both input
and output sides
- Current cosnumption:12v-24v 50ma
6-12v version 80ma
- 8 Amp relay output contact current
rating @ 30VDC
- European-style, easy terminate,
input
and output connectors.
- .090 thick, high quality circuit board.
- Dimensions: L18.8X2.5
Order options
GPRB-16-12/25: 12 or 24V AC/DC inputs
GPRB-16-6/12: 6 or 12V AC/DC inputs
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|
URM-
1, URM- 4, URM- 8 Universal
Relay Modules
The URM-X series of relay boards
offer system integrators an easy, truly
universal solution for
controlling hi or
low current
devices such as electric
locks, lights, sirens, etc with literally
ANY type
of low voltage, dry contact or
open collector input signals.
Recently updated to accept
1.5-24VDC
input voltages.
- Single or multi-zone electric lock,
lighting control, etc.
- Use low-current outputs from
burglar alarms, fire alarms,
access
systems, CCTV systems,
to control hi-current devices.
1.5 to 24vdc power input.
Accepts these trigger types:
Open collector or open drain
Dry contact NC or NO.
TTL or CMOS levels
Any voltage from 1.5Vdc to
24Vdc
Polarity protected power input.
Each channel has its own
low-dropout 5 Volt regulator
4.7K Ohm input impedance
8 Amp 120VAC form C relay output.
Jumper selectable trigger type.
Jumper selectable Invert or buffer input signal for each channel.
European-style, easy terminate,
input
and output connectors.
LED status indicators for each relay.
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|
ULC
- 1, ULC - 4, ULC - 8 Universal
Level Converters
The ULC-X series of level converters
offer system integrators an easy, truly
universal, solution for interfacing
equipment with different
input and output voltage requirements. The
ULC outputs can also directly drive low
current devices such as electric
locks, strobes, etc.
- Convert higher DC voltage levels
to lower DC voltages.
- Convert lower voltage levels
to higher voltages.
- Convert dry contact or open
collector inputs to voltage outputs.
- 5 to 24vdc power input.
- Accepts these trigger types:
Open collector or open drain.
Dry contact NC or NO.
TTL or CMOS levels
Any voltage from 5Vdc to 24Vdc
- 4.7K Ohm input impedance.
- Up to 1 Amp 24Vdc sink / source
outputs
- Outputs short circuit protected with automatic re-settable fuse.
- Jumper selectable trigger type.
- Jumper selectable Invert or buffer
input signal for each channel.
- European-style, easy terminate, input
and output connectors.
- Dual LED status indicators for each
channel.
- Outputs can be set for sink only,
source only or BOTH.
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|
SVRB - 3.3, 5, 6, 8, 9, 10, 12,
15, 18, 24
Simple Voltage Regulator Board
The SVRB-X is a simple, low cost ,
linear voltage regulator board
designed for low current loads using higher available Voltage sources. Ideal for
point of use power. It accepts regulated DC, unregulated DC or up to 24V AC
power input Voltages. Available in ten different output voltages.
- Compact size
- Automatic short circuit and thermal shutdown.
2 Watt power dissipation
- 1 amp maximum current draw.
- AC or DC (polarity insensitive)
voltage input.
- sticky backed tape Mounting.
- Dimensions L1.25 x W1.0
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|
DS1 Door Contact Shunt Timer
The DS1 is designed for use on
egress doors (with no card
reader) equipped with magnetic
locks or strikes, a request to exit
device such as a PIR or electric
panic bar, and a door contact
switch. After an RTE (request to exit)
is
received, the door contact shunt
time (prop time) begins. If the door is
left
open, after the timer times out,
an alarm will result. If the door
closes before the timer time
ends (prop time), the timer is
automatically
reset and the
contact is
re-armed.
- LED alarm indicator
- N.C. dry contact alarm
input,
output and RTE.
- Momentary or maintained
RTE signal.
- Jumper settable for auto-reset
timer (when door closes) or
time-out after RTE ends.
- Prop timer is re-triggerable while
door is open.
- Adjustable prop timer 1 to 20
seconds or 1 to 20 minutes.
- Jumper setting for minutes or
seconds selection
- Power input polarity protected.
- Easy cable run
terminations.
- Power: 12 to 24VDC@ 50mA.
- Blue power indicator.
- Dimensions: W 2.14 x L1.5
|
E-mail or
Call For Pricing
Download Product Specification Sheet
View Installation Instructions
|